Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
Disposable Surgical Breathing mask
平面口罩机参数:
Semi-Automatic Mask Machine
l Power supply: 3.3KW mono phase
l Mask Size: 175mm*80-100mm (two or three layers)
l Nonwoven (GMS): 10-50g
l Capacity: 120 to 150pcs/min
l Dimension(L*W*H):3800mm*500mm*1400mm
l Net Weight: about 1000kg
焊接机参数:
Welding Machine
l Capacity: 5 to 10pcs/min
l Power supply: 8.5KW mono phase
l Compressed Air connection: 0.5 to 0.7Mpa
l Dimension(L*W*H): 900mm*650mm*1380mm
l Net weight: approx. 50kg
KN95口罩机参数:
N95 Mask Machine
l Capacity: 130 to 160pcs/min
l Dimension(L*W*H): 1037*855*1780
l Power Supply 15.3kw mono phase
l Net Weight: approx.: 1500kg
Tel: +86-25-8461 0201
Website: www.hiclover.com
Email: sales@hiclover.com
Email: hicloversales@gmail.com
2020-04-06
30kgs medical waste incinerator Model TS30 PLC
Items/Model |
TS30 PLC |
Principle |
Waste Incineration |
Burn Rate |
Average 30kgs/hour |
Fuel Type |
Diesel Oil/Natural Gas |
Control Mode |
Programmable Logic Controller(PLC) Panel |
Primary Combustion Chamber |
0.33 m3 |
Internal Dimensions(Primary) |
750x750x600 mm |
Secondary Combustion Chamber |
0.18 m3 |
Internal Dimensions(Secondary) |
400 x 750 x 600 mm |
Smoke Filter Chamber |
Yes |
Feed Mode |
Manual |
Voltage |
220V |
Power |
0.5Kw |
Oil Consumption |
10.2―20.0 kgs/hour |
Gas Consumption |
9.8―20.0 m3/hour |
Temperature Monitor |
Digital Display |
Temperature Protection |
PLC Control |
Time Setting |
PLC Control, 0-120 Minutes |
Oil Tank |
100 Liters |
Waste Feed Door |
550x500mm |
Chimney |
5.0 Meter |
Chimney Type |
Stainless Steel |
Primary Chamber Temperature |
800℃–1000℃ |
Secondary Chamber Temperature |
1000℃-1200℃ |
Residency Time |
2.0 Sec. |
Gross Weight |
3000kgs |
External Dimensions |
1750x1200x1400 mm |
Tel: +86-25-8461 0201
Website: www.hiclover.com
Email: sales@hiclover.com
Email: hicloversales@gmail.com
legislation the emission limit value for NOx does not apply to plants only incinerating hazardous waste
Directive 2000/76/EC of the European Parliament and of the Council of 4 December 2000 on the incineration of waste. Exemptions for NOx may be authorized by the competent authority for existing incineration plants: ― with a nominal capacity of 6 tonnes per hour, provided that the permit foresees the daily average values do not exceed 500 mg/m3 and this until 1 January 2008, ― with a nominal capacity of >6 tonnes per hour but equal or less than 16 tonnes per hour, provided the permit foresees the daily average values do not exceed 400 mg/m3 and this until 1 January 2010, ― with a nominal capacity of >16 tonnes per hour but <25 tonnes per hour and which do not produce water discharges, provided that the permit foresees the daily average values do not exceed 400 mg/m3 and this until 1January 2008.
Until 1 January 2008, exemptions for dust may be authorized by the competent authority for existing incinerating plants, provided that the permit foresees the daily average values do not exceed 20 mg/m3.
Since, Hydrogen chloride (HCl), Hydrogen fluoride (HF) , Sulphur (S) are not present in feed so, these will not be present in flue gas. ( B ) Half Hourly Avg. Values Values Unit
100 % ( A ) 97 % ( B) mg/m3 1 Total dust 30 10 mg/m3
2 Gaseous and vaporous organic substances, expressed as total organic carbon
20
10
mg/m3 3 Hydrogen chloride (HCl) 60 10 mg/m3 4 Hydrogen fluoride (HF) 4 2 mg/m3 5 Sulphur dioxide (SO2) 200 50 mg/m3
6 Nitrogen monoxide (NO) and nitrogen dioxide (NO2), expressed as nitrogen dixoide for existing incineration plants with a nominal capacity exceeding 6 tonnes per hour or new incineration plants
400 ( * )
200 ( * )
mg/m3
WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters
Nanjing Clover Medical Technology Co.,Ltd.
Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat) Website: www.hiclover.com Email: sales@hiclover.com Email: hicloversales@gmail.com
Until 1 January 2010, exemptions for NOx may be authorized by the competent authority for existing incineration plants with a nominal capacity between 6 and 16 tonnes per hour, provided the half-hourly average value does not exceed 600 mg/m3 for column A or 400 mg/m3 for column B.
Since Hydrogen chloride (HCl), Hydrogen fluoride (HF) , Sulphur (S) are not present in feed so, these will not be present in flue gas.
( C ) All average values over the sample period of a minimum of 30 minutes and a maximum of 8 hours.
Sr. No. All average values over the sample period of a minimum of 30 minutes and a maximum of 8 hours Unit
1 Cadmium and its compounds, expressed as cadmium (Cd)
Total 0.05
Total 0.1 *
Mg / m3
2 Thallium and its compounds, expressed as thallium (Tl) 3 Mercury and its compounds, expressed as mercury (Hg) 0.05 0.1 * Mg / m3 4 Antimony and its compounds, expressed as antimony (Sb)
Total 0.5
0.1 *
Mg / m3 5 Arsenic and its compounds, expressed as arsenic (As) 6 Lead and its compounds, expressed as lead (Pb) 7 Chromium and its compounds, expressed as chromium (Cr) 8 Cobalt and its compounds, expressed as cobalt (Co) 9 Copper and its compounds, expressed as copper (Cu) 10 Manganese and its compounds, expressed as manganese (Mn) 11 Nickel and its compounds, expressed as nickel (Ni) 12 Vanadium and its compounds, expressed as vanadium (V)
These average values cover also gaseous and the vapour forms of the relevant heavy metal emissions as well as their compounds.
(d) Average values shall be measured over a sample period of a minimum of 6 hours and a maximum of 8 hours.
The emission limit value refers to the total concentration of dioxins and furans calculated using the concept of toxic equivalence in accordance with Annex I.
Dioxins and furans = 0,1 ng/m3
(e) The following emission limit values of carbon monoxide (CO) concentrations shall not be exceeded in the combustion gases (excluding the start-up and shut- down phase):
― 50 milligrams/m3 of combustion gas determined as daily average value; ― 150 milligrams/m3 of combustion gas of at least 95 % of all measurements determined as 10-minute average values or 100 mg/m3 of combustion gas of all measurements determined as half-hourly average values taken in any 24- hour period.
Exemptions may be authorized by the competent authority for incineration plants using fluidized bed technology, provided that the permit foresees an emission limit value for carbon monoxide (CO) of not more than 100 mg/m3 as an hourly average value.
About Hiclover Medical Enviromental
HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project.
We supply single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators for laboratory, clinic, hospital, medical center, hygiene clinical waste destruction with medical disposable, biological waste, medical plastic waste, hazardous waste, red bag waste, needle disposal, gauze and bandages, sealed sharp containers, pathological waste, trace-chemotherapeutic wastes, etc.
Our range of incinerators cater for small to large scale animal cremation related businesses, such as poultry farms, cattle farms, sheep farms, pig farms, stables, kennels, testing laboratory, catteries, pet crematoriums.
The incinerator burn waste in primary combustion chamber and burn the smoke from primary combustion chamber again to make sure environmentally friendly with no black smoke, smelless, reduce pathogenic bacteria infection.
System solutions for medical waste environmental, including waste incineration, smoke emission treatment, high-temperature sterilization, ultraviolet sterilization lamp, waste shredder, needle destroyer, medical waste package, sharp containers, etc.
The pet cremation equipment humanized design with movable platform, small space covers for modern pet cremation business owner all over the world.
The containerized mobile incinerator mounted in ISO container before leave factory, pre-installation, no incineration house build construction, movable by truck and ultraviolet lamp sterilization inside.
HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We a re trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan.
We are china incinerator manufacturer, contractor and exporter. Manufacturer make reasonable price for incinerator customer, supply medical incinerator, hospital incinerator, animal incinerators, hog incinerators, pet cremation equipment, small incinerator, pet incinerator, animal incinerator, portable incinerator, small animal incinerator, infectious waste pyrolysis machine, laboratory incinerator. HICLOVER help customer reduce purchase budget, custom made function, quality products and friendly service.
Required Specifications for Mobile Incinerator
Operational Capabilities
- PROCESS MINIMUM 1 TON PER DAY
- OPERATED WITH LIMITED TRAINING
- REGULAR MAINTENANCE CAN BE COMPLETED WITH LIMITED TRAINING
- COMPLIES WITH EURO / OR US-EPA EMISSION STANDARDS
- ABILITY TO BURN WASTE LUBRICANTS (POL)
- HANDLE ORGANIC SOLIDS (TO INCLUDE RMW)
- DEPLOYABLE
- MOBILE
- 24 HRS OF CONTINUOUS USE
- AUTOMATIC LOADING SYSTEM
- AUTOMATED ASH REMOVAL SYSTEM
- GAS SCRUBBING SYSTEM
- 95% REDUCTION OF SOLID WASTE
- OPERATE OFF DIESEL OR FUEL OIL
- CAPABLE OF BURNING 4 UNITS OF WASTE PER UNIT OF FUEL
- ABLE TO TAKE ALL COMBUSTIBLE WASTE TO INCLUDE: PAPER, PLASTIC, CARDBOARD, FOOD, USED OILS, SLUDGE, OILY RAGS, WOOD
- NO PRE-TREATMENT OF WASTE REQUIRED
- FIVE (5) YEAR COMPONENT WARRANTY
Technical Specifications
- OPERATION MANUAL AND TRAINING MANUAL FOR EACH INCINERATOR
- SET UP AND INSTALLATION INSTRUCTION MANUALS
- BLUE PRINT/ SCHEMATIC PROVIDED THAT OUTLINES THE PHYSICAL DIMENSIONS OF THE 20’ INCINERATORS
- INCINERATORS COMPOSED WITH HEAVY DUTY WELDED CONSTRUCTION
- OPERATED AND TRANSPORTED IN 20’ INCINERATORS (CONTAINERS)
- FULL FRONT AND OPTIONAL REAR ACCESS
- PRIMARY / SECONDARY TEMPERATURE CONTROLS